To increase therapeutic effectiveness, RITM OKB ZAO designed a new version of SCENAR devices: SCENAR-M (SCENAR-1-NT featuring musical frequency modulations).

OLM modifications
At a customer’s request OLM-modifications for local therapy made as gloves, sleeves, hats, shorts, jackets, slippers, etc. can be delivered.

STABILAN-3D The complex is designed for recording, time-tracking, qualitative evaluation, analyzing and simulating human locomotor structures in 3D space simultaneously with the position of center of gravity

 



(Asked price)

Enlarge

SCENAR DE new performance capabilities and functionalities

As compared with previous models and their versions, SCENAR-DE features a materially new stimulation mode that is provided by built-in software-controlled switch and dynamic electrodes (also known as multiple electrode). This mode can be defined as a spatially modulated stimulation.

Presentation

SCENAR-DE provides the following spatial modulation modes:

  • Extended spatially modulated stimulation (flat dynamic electrode, area of exposure - about 100 sq.cm)
  • local spatially modulated stimulation (local dynamic electrode, area of exposure – about 10-15 sq.cm)
  • point spatially modulated stimulation (point dynamic electrode, area of exposure – about 1 sq.sm)
  • local spatially modulated stimulation using the rectal-vaginal electrode (50-100 sq.cm)

There are electrodes that are delivered with “ SCENAR DE ” devices in the pictures. More electrodes for SCENAR DE manufactured by OKB “RITM” are coming soon.

Besides, the complete delivery set of SCENAR DE includes a remote control which is aimed mainly to let the patient select the stimulation strength during the session. See also Searching for asymmetry signs using the threshold of sensitivity.
Enlarge
Enlarge

The experience we have today gives every reason to assert obvious advantages of using SCENAR-DE in conventional SCENAR-therapy practice in the following clinical situations:

  1. Extended back pain (no clear outlines) spatially modulated stimulation for 20 min at the longest, using the flat dynamic electrode on the entire area of complaint as a single start-up session (minimum effect – less intensive and better localized pain, maximum effect – complete pain relief).
  2. Local inflammatory processes (after injections, to prevent the development of  inflammatory processes, to provide most physiological permeation of drugs into the body – point or local dynamic electrode for 20 min at the longest., 1-2 sessions).
  3. In SCENAR-therapy of gynecological diseases, prostatitis, hemorrhoids, lumbosacral pains according to usual practice – spatially modulated stimulation for 20 min at the longest, using the rectal-vaginal electrode as a finishing procedure dramatically reduces the treatment period.  

Special therapy programs

Special therapy programs are intended for use in gynecology mainly. However, there is an experience of applying them to treat particular urological and proctologic pathologies. See application experience for detail.

5 special therapy programs :

  • Left oophoritis
  • Right oophoritis
  • Bilateral oophoritis
  • Metroendometritises
  • Hormonal state recovery

Electrode arrangement for the “Left oophoritis”, “Right oophoritis”, “Bilateral oophoritis”, and “Metroendometritises” programs


Electrode arrangement for the “Hormonal state recovery” program

The remote control is given to the patient who can set a comfortable strength of stimulation using the controls.

User's therapy programs

User's therapy programs are intended to make it easier to make a therapy session when a local zone has to be treated for long. To do this, the therapist can create 1 to 3 his/her own therapy programs using either cavity or superficial electrodes. A therapy program may include from 1 to 5 treatment modes. For each mode the following parameters are to be chosen:

  • Mode and rate of electrode switching
  • Stimulation time
  • Stimulating pulse parameters (frequency, modulation, intensity, gap)
The electrodes delivered with the device can be combined variously. The design of the superficial electrodes allows to unite them into groups as shown in the pictures.
Electrode arrangements
Enlarge
Enlarge
Enlarge
Enlarge
Enlarge
Enlarge
Enlarge

Registration certificate ¹ÔÑÐ 2008/02904