SCENAR  
Stabilan  
Rista  
OLM  
Myomonitor  
Others  

 
SCENAR  
Rista  
OLM  

 
 

SCENAR-1-NT
To increase therapeutic effectiveness, RITM OKB ZAO designed a new version of SCENAR devices: SCENAR-M (SCENAR-1-NT featuring musical frequency modulations).

OLM modifications
At a customer’s request OLM-modifications for local therapy made as gloves, sleeves, hats, shorts, jackets, slippers, etc. can be delivered.

STABILAN-3D The complex is designed for recording, time-tracking, qualitative evaluation, analyzing and simulating human locomotor structures in 3D space simultaneously with the position of center of gravity

 


Biofeedback computer stabiloanalyzer
(Ask for Price)
Enlarge  

The complex of hardware and method-based software based on the computer stabilography is intended for diagnosing human body equilibrium disorders and locomotor pathologies, treating motor coordination disorders, as well as for carrying out occupational selection and pre-route and post-route check of people employed in transport-related occupations.

Fields of Application :

  • diagnostics and evaluation of equilibrium disorders (in neurology, vertebral neurology, neurosurgery, otolaryngology, orthopedic traumatology, osteopathy);
  • biofeedback-based rehabilitation of patients with equilibrium and locomotor disorders;
  • basic research in the field of biomechanics of movements in the upright position;
  • occupational selection, career-guidance, pre-route and post-route check of people employed in transport-related occupations;
  • physical training and sport.

Stabiloanalyzer includes

  • tensometric platform;
  • a PC not older than Celeron 566 ( 128 Mb, SVGA, HDD 4 Gb, 8 Mb video display card that fully supports Direct X, COM 1 or COM 2, FDD, CD-ROM) and higher, Windows 98, Me, NT, 2000 or XP operating system;
  • method-based software;
  • adjustable second monitor platform.

Stabilography development in ZAO "OKB "RITM" has a long rich history and contributed to creative relations and ties establishing.

Registration certificate ¹29/03051000/1885-01

Conformance certificate ¹ÐÎÑÑ RU.ÈÌ02.Â15923

 

   

 

Basic model Recording and analyzing the trajectory of the human center of pressure on the surface.

Basic model with a rhythmogram (pulse) channel The basic model is completed with a rhythmogram channel with the analysis of heart rate variability

Additions to the basic model
  Myomonitor. The device is designed for long-term PC-based recording and subsequent processing of the electromyogram envelope curves in order to evaluate their time characteristics and amplitude curves.